Standard Takeoff by Division
Sitework/Site Utilites
- Overall site area- Acre and SF (Acre = SF/43,560)
- SWPPP
- Perimeter protection by type- LF
- Intake protection- EA
- Temporary detention pond structures- EA
- Construction entrance- SF
- Note any temporary stabilization needed by type and quantity
- Demolition/relocation by type
- Building- SF
- Paving/Sidewalk- SF
- Utilities by type- LF, structures count, note relocations
- Water tap/Sanitary tap removals- EA
- Significant miscellaneous items- retaining walls, sign footings, etc
- Proposed building- SF (verify to Architectural/Structural)
- Pavements and sidewalks by type and thickness- SF
- Curb and gutter for asphalt paving- LF
- Site Utilities
- Water- LF, sizes
- Sanitary- LF, sizes
- Storm
- Pipe footage by size/type- LF
- Structure count by type
- Sand/oil or grease interceptor size
- Fire hydrants
- Street cuts- count, SF
- Roof drains- confirm counts and sizing with Architectural and MEP
- Site Furnishings
- Monument or other signage- Include in concrete, masonry, etc as needed
- Car chargers
- Benches, canopies, bike racks, etc.
- Site Fencing
- Temporary- LF, include number of gates needed
- Permanent- LF by type, include number of gates needed
- Retaining Walls- LF by type, note any retaining wall over 5’ in height for engineering
- Trash Enclosures
- LF wall by type (masonry, wood, etc.)
- Overall SF
- Gates- LF by type
- Landscaping/Irrigation
- Overall green area- SF
- Sod/Seed by type-SF
- Hardscape/Planter area- SF
- Plant schedule by type- EA
- Overall irrigation/zones- SF
- Site Electrical
- Site lighting- total poles and bases- EA
- Monument and other powered signage- EA
- Car charging stations by type- EA
- Transformer- EA
Demolition (Structure)
- Overall square footage- SF
- Exterior wall/façade- LF
- Interior- SF
- SOG/Trenching- SF
- Flooring- SF
- As needed
Concrete
- Perimeter footing by type- LF
- Interior continuous footing by type- LF
- Isolated footings by type- EA
- S.O.G.- SF by type and thickness
- Equipment/Elevator pits- EA
- Indicated thickend slabs, etc- SF or LF as necessary
- Site concrete per Sitework
- Second floor/mezzanine by type- SF
- Underslab radon mitigation- LF
Masonry
- Structural CMU- LF and height
- Exterior CMU/Splitface- SF
- Elevator and stair shafts- EA plus height
- Footing block- LF
- Exterior veneer by type- SF
Steel
- Columns by type- EA
- Beams by size- LF
- Decking- Mezzanine and Roof by type- SF
- Roof openings/Frames
- Miscellaneous Steel
- Stair flights by type- EA
- Lintels by type/size- EA
- Handrails- EA
- Elevator hoist beam and ladder
- Exterior
- Bollards- EA
- Trash Gates/Posts- EA and size
- Balcony rail by type- LF
- Handrail/guardrail by type- LF
Framing
- Wood Framing- overall SF
- Steel stud framing
- Exterior Framing/sheathing- SF
- Interior framing- SF
- Flat roof framing
- Parapet sheathing- SF
- Other
- Blocking/backing
- Parapet cap- LF
- ADA restrooms- EA
- Specialty items- TVs, sinage, etc- EA
Trim
- Wood stair flights- EA
- Millwork items by type-EA
Cabinets/Countertops
- Multifamily
- Lower/Upper count by unit type- EA
- Tops by unit type- SF
- Commercial
- List loacation/type
- Tops by type- SF
Insulation
- Note sound insulation in interiors (bathrooms, above ACT)- SF
- Spray foam insualtion by type- SF
Fire Stopping
- Note non-MEP penetrations (sprayed columns, intumecent paint, etc) by type- SF
Sheet Metal/Flashings
- ACM or Metal Panels by type- SF
- Flashings at dissimilar materials (siding to brick, etc.)- LF
- Soffit/Fascia- LF
EIFS, Siding, Other Exterior
- Type and color- SF
- Siding by type- SF
- Rain screen as needed by type- SF
Waterproofing
- Elevator pits- EA
- Foundation walls- SF
- Fluid applied at exterior finish- SF
Caulking
- Exterior
- Brick joints- LF
- Dissimailar materials- LF
- Building expansion joints- LF
- Doors/windows in masonry- EA
- Pavement expansion joints- LF
- Interior
- Doors and windows- EA
- HM frames- EA
Doors and Windows
- Aluminum storefront- SF
- Curtainwall- SF
- HM Frames- EA
- Door slabs by type- EA
- Glass inserts by type- EA
- Windows/patio doors by type- EA
- OH doors by type/size
Roofing
- Roofing by type-SF
- Insulation requirement
- Roof hatch- EA
- Walkpads- EA
- Sheetmental cap-LF
- Gutter- LF
- Downspouts- Size, EA
Drywall
- Plan Sf by type- SF
- Ceiling- SF
- Note finish
ACT
- List by type- SF
- Drywall on grid system- SF
Flooring
- Floor covering by type- SF
- Sealed concrete- SF
- Polished concrete- SF
- Note special transisions, joint isolation, etc
- Base by type- LF
Painting
- Plan Sf to be painted
- Exposed ceilings-SF
- Note duct/conduits, etc. to be painted
- Exterior
- Walls-SF
- Bollards
- Trash gates, etc
- Other items of note
Specialties
- Grab bars by type- EA
- Bathroom accessories by type- EA
- Toilet partitions
- Fire extinguishers and cabinets by type- EA
- Knox box- EA
- Mailboxes by type- EA
Micellaneous Equipment
- Appliances by type/unit type- EA
Window Treatments
- By type/size- EA
- Mechanical shades- SF
Elevators/Lifts
- By type- EA
- Stops
Plumbing
- Multifamily
- Fixture count by unit type- EA
- Sink
- Toilet
- Lav
- ADA
- WH
- Building system items
- Boiler/water heater by type- EA
- Fixture count by unit type- EA
- Commercial
- Overall bathroom count- EA
- Fixture count by type- EA
- Trench Drains- LF
- Roof Drains- EA/LF
- Gas Piping- LF
- Floor sinks/condensate drains- EA
- RPZ/Backflow- EA
- Meters(domestic, itrrigation)- EA
- Landscaping manifold-EA
Mechanical
- Multifamily
- System by unit type
- Individual AHU- EA
- Exhaust fans-EA
- Dryer duct-EA
- Fresh air duct- EA
- Commons systems by type- EA
- System by unit type
- Commercial
- RTU by type/size- EA
- Make up air by type/size- EA
- CO/NOX system- EA
- Exhaust Fans by type- EA
- Refrigeration system/Coolers by type- EA
- Ansul system by type-EA
Fire Sprinkler
- Overall Coverage by type (13/13R)- SF
- Dry system- SF
- Dry pendant heads (patios, canopies, etc)- EA
- Riser size- Verify with site plan
- Concealed heads- EA
Electrical
- Service size- Voltage/Amperage
- Panel count by type/size-EA
- Lighting by type- EA
- Cove or linear lighting- LF
- Lighting controls/zones by type (non standard switching)
- Floor boxes- EA
- Elevator/Equipment by type- EA
- Car chargers by type- EA
- Powered signage by type-EA
- Roof power items- EA
- Site electrical items per sitework
- Low voltage by type (non typical)- EA